Systems examples - Uniquely designed

On request, we test systems, which are precisely adapted to your individual requirements. No matter what industry, we find the optimal solution for almost any electrical safety test. Even after commissioning you will receive an extensive after sales service. Here is a small excerpt from our already implemented customer-specific test systems. Request your favorite test system.

Test system for current sensors

Test system for current sensors
Test system for current sensorsTest system for current sensorsTest system for current sensorsTest system for current sensors
  • High voltage test up to max. 5500 VAC / 100mA
  • Function test with triple rated current
    • All of the static and dynamic characteristics are acquired (accuracy, linearity, etc.)
  • Printing on sensor
  • Turntable with 4 stations:
    • Equipping and de-equipping
    • High voltage test
    • Function test
    • Printing
  • Pass / Fail display
  • Simultaneous test of two DUTs
Technische Daten

Hochspannungstest

- Potential

- Sicherheitsstrombegrenzung

1500 VDC / 4 mA
frei

ja

Isolationstest

- Potential

- Sicherheitsstrombegrenzung

500 VDC / 50 MOhm

frei

ja

Schutzleitertest

- Widerstandsmessung (EN 60 335)

 

 

- Spannungsmessung (EN 60 204)

- Leerlaufspannung

max. 30 AAC

bis 20 AAC, max. 500 mOhm
bei 25 AAC, max. 400 mOhm
bei 30 AAC, max. 300 mOhm

0 - 4 VAC

6 V und 12 V

Gehäuse 14" / 3 HE
Netz 230 V / 50 Hz oder 115 V / 60 Hz