Systems examples - Uniquely designed

On request, we test systems, which are precisely adapted to your individual requirements. No matter what industry, we find the optimal solution for almost any electrical safety test. Even after commissioning you will receive an extensive after sales service. Here is a small excerpt from our already implemented customer-specific test systems. Request your favorite test system.

Test Station for Hedge Clippers and Lawn Trimmers

Test Station for Hedge Clippers and Lawn Trimmers
  • Safety and function test station for hedge clippers:
    • Braking time, blocking current and number of revolutions measurement
    • Voltage, current and active power measurement
    • High voltage test
  • Inlet position for hedge clippers
  • Function test station for lawn trimmers:
    • Voltage and current measurement
  • Remote maintenance
Technische Daten

Hochspannungstest

- Potential

- Sicherheitsstrombegrenzung

1500 VDC / 4 mA
frei

ja

Isolationstest

- Potential

- Sicherheitsstrombegrenzung

500 VDC / 50 MOhm

frei

ja

Schutzleitertest

- Widerstandsmessung (EN 60 335)

 

 

- Spannungsmessung (EN 60 204)

- Leerlaufspannung

max. 30 AAC

bis 20 AAC, max. 500 mOhm
bei 25 AAC, max. 400 mOhm
bei 30 AAC, max. 300 mOhm

0 - 4 VAC

6 V und 12 V

Gehäuse 14" / 3 HE
Netz 230 V / 50 Hz oder 115 V / 60 Hz