Systems examples - Uniquely designed

On request, we test systems, which are precisely adapted to your individual requirements. No matter what industry, we find the optimal solution for almost any electrical safety test. Even after commissioning you will receive an extensive after sales service. Here is a small excerpt from our already implemented customer-specific test systems. Request your favorite test system.

System Example for Electric Tools

System Example for Electric Tools
System Example for Electric ToolsSystem Example for Electric Tools
Technische Daten

Hochspannungstest

- Potential

- Sicherheitsstrombegrenzung

1500 VDC / 4 mA
frei

ja

Isolationstest

- Potential

- Sicherheitsstrombegrenzung

500 VDC / 50 MOhm

frei

ja

Schutzleitertest

- Widerstandsmessung (EN 60 335)

 

 

- Spannungsmessung (EN 60 204)

- Leerlaufspannung

max. 30 AAC

bis 20 AAC, max. 500 mOhm
bei 25 AAC, max. 400 mOhm
bei 30 AAC, max. 300 mOhm

0 - 4 VAC

6 V und 12 V

Gehäuse 14" / 3 HE
Netz 230 V / 50 Hz oder 115 V / 60 Hz

 

This test system has been designed to perform the end test for electric hand circular saws. The DUTs have double insulation and belong to safety class II. Therefore the earth bond test is not required, however the high voltage flash test is all the more important.

The housing screws are pneumatically contacted with Kelvin pins and the high voltage applied from L+N to external exposed metal. A withstanding voltage tester with back measuring (4-wire technique) guarantees together with the Kelvin pins that all points are contacted and that the power supply plug of the DUT has been connected. This way there is no danger of a faulty measurement caused by not making contact.

In addition there is a function test evaluating the current consumption of the DUT. Then a pneumatic cylinder blocks the saw blade and the full load current is tested by the test system. After a further current test a flutter test of the saw blade is performed. Which means that the saw blade is being tested in the longitudinal direction for mechanical deviations (beat or balancing of the blade). Finally the braking/retardation time between switching off the DUT and the standstill of the saw blade is tested.

The above test system is just one of the examples possible for test systems made to specification.

  • PC remote controlled test system with WINDOWS software
  • withstanding voltage test in 4-wire technique (back measuring)
  • test cage with automatic interlock
  • DUT adapter with independent, pneumatic contacting of Kelvin pins
  • function tests allow an exact evaluation of the DUT