Systems examples - Uniquely designed
On request, we test systems, which are precisely adapted to your individual requirements. No matter what industry, we find the optimal solution for almost any electrical safety test. Even after commissioning you will receive an extensive after sales service. Here is a small excerpt from our already implemented customer-specific test systems. Request your favorite test system.
Cable Test in heated Water Bath
- 2 water basins, heatable up to 85 °C
- Independent control of test voltage, test time
and temperature of each water basin - High voltage test up to 5500 VAC / 100 mA
and 6000 VDC / 100 mA - Insulation resistance test up to 6000 VDC / 1 GOhm
| Technische Daten | |
| Hochspannungstest - Potential - Sicherheitsstrombegrenzung | 1500 VDC / 4 mA ja |
| Isolationstest - Potential - Sicherheitsstrombegrenzung | 500 VDC / 50 MOhm frei ja |
| Schutzleitertest - Widerstandsmessung (EN 60 335)
- Spannungsmessung (EN 60 204) - Leerlaufspannung | max. 30 AAC bis 20 AAC, max. 500 mOhm 0 - 4 VAC 6 V und 12 V |
| Gehäuse | 14" / 3 HE |
| Netz | 230 V / 50 Hz oder 115 V / 60 Hz |