Test cages
Test cage with integrated device plug-in compartment
If, in accordance with EN 50 191, a test station with automatic protection against accidental contact has to be installed, a test fixture would be the perfect solution. The safety installation against indirect contact must guarantee that there are only voltages at the DUT when the enclosure lid is closed. A single fault must not prevent the disconnection at opening.
Features
The cage is equipped with two safety limit switches. The DUT is connected via 4 mm laboratory sockets, power outlet or multiple connectors according to DIN 41622. For the connection tester - safety relay board connectors of type ST 02 (with connected cable) are applied. The built-in safety relay board with certified acceptance protocol offers the required protection from hardwarelike disconnection. There are two cut-outs at the back of the cage, e. g. for printer or warning lamp connection.
| Types | |
| HB 2000 | outside dimension: h=660 mm, B=500 mm, f=630 mm |
| inside dimension: H=200 mm, B=410 mm, t=410 mm plug-in 19'' / 4 HU | |
| HB 2100 | outside dimension: h=705 mm, B=500 mm, f=800 mm |
| inside dimension: H=200 mm, B=410 mm, t=490 mm plug-in 19'' / 5 HU | |
- conforms to CE, in accordance with EN 50 191
- enclosure made of grey PVC
- swivel acrylic glass lid with damping cylinder
- safety limit switch, automatic contact break
Accessories
- connection units for our safety testers