High voltage test devices

HA 5012L

HA 5012L

With these high voltage testers air and leakage paths are tested. Measurement of test voltages is specified in the relevant standards (IEC, EN, UL, BS, VDE, etc.). 

As a general rule applies:    rated voltage x 2 + 1000 V

The high voltage tester series HA 5012L has been developed solely for application in automatic test systems.
These devices are remote controlled via a potential free 24 VDC / PLC remote control interface. Current and voltage are supplied via analogue, potential free signals (0 - 10 VDC). Analogue inputs (0 - 10 VDC) are available for rated value defaults.

Technische Daten

Hochspannungstest

- Potential

- Sicherheitsstrombegrenzung

1500 VDC / 4 mA
frei

ja

Isolationstest

- Potential

- Sicherheitsstrombegrenzung

500 VDC / 50 MOhm

frei

ja

Schutzleitertest

- Widerstandsmessung (EN 60 335)

 

 

- Spannungsmessung (EN 60 204)

- Leerlaufspannung

max. 30 AAC

bis 20 AAC, max. 500 mOhm
bei 25 AAC, max. 400 mOhm
bei 30 AAC, max. 300 mOhm

0 - 4 VAC

6 V und 12 V

Gehäuse 14" / 3 HE
Netz 230 V / 50 Hz oder 115 V / 60 Hz

 

Technical data

output AC

short-circuit current

transformer capacity

0.2 - 2.5 kV / 100 mA  |  0.5 - 5 kV / 50 mA

200 mA

500 VA

potential free
4-wire technique

yes

plug-in 19" / 4 HU
power supply 230 V / 50 Hz or 115 V / 60 Hz

  • conforms to CE, in accordance with EN 50 191
  • electronic, wear-proof cutting-in via semi-conductor relay in zero pause
  • analogue instrument class 1.5 for voltage
  • analogue instrument class 1.5 for current
  • secondary measurement of current and voltage
  • rear connections for all interfaces
  • potential free PLC remote control interface
  • analogue programming of release current (0 - 10 VDC)
  • potential free analogue output for voltage (0 - 10 VDC)
  • potential free analogue output for current (0 - 10 VDC)
  • voltage programming (0 - 230 V or 0 - 115 V)
  • separate earthing contact
  • connection for warning lamp set

Options

  • current range 1 mA / 10 mA