Multi tester
PM 3301E (For testing acc. to EN 60 204)
Safety tester PM 3301D allows safety tests according to EN 60204 (VDE 0113).
The method of connection has been designed in particular for testing of machines and switching cabinets: All tests can be performed serially with one-time contacting.
Special attention has been paid to a user-friendly operation by means of a multiple line LC-display and function keys with clear text. Available is a programme memory for 100 test programmes with 300 steps each. Via a comfortable WINDOWS-software remote control with a PC is possible. The printer interface allows protocols of all parameters and test and measurement results according to standard.
| Technische Daten | |
| Hochspannungstest - Potential - Sicherheitsstrombegrenzung | 1500 VDC / 4 mA ja |
| Isolationstest - Potential - Sicherheitsstrombegrenzung | 500 VDC / 50 MOhm frei ja |
| Schutzleitertest - Widerstandsmessung (EN 60 335)
- Spannungsmessung (EN 60 204) - Leerlaufspannung | max. 30 AAC bis 20 AAC, max. 500 mOhm 0 - 4 VAC 6 V und 12 V |
| Gehäuse | 14" / 3 HE |
| Netz | 230 V / 50 Hz oder 115 V / 60 Hz |
| Technical data | |
| high voltage test potential safety current limited | 1500 VDC / 4 mA yes |
| insulation test potential safety current limited | 500 VDC / 50 MOhm free yes |
| protective wire test resistance measurement (EN 60 335)
no-load voltage | max. 30 AAC till 20 AAC, max. 500 mOhm 0 - 4 VAC 6 V and 12 V |
| plug-in | 14" / 3 HU |
| power supply | 230 V / 50 Hz or 115 V / 60 Hz |
Special features
- conforms to CE, in accordance with EN 50 191
- 3 in 1 tester
- automatic test process
- internal change-over for all tests with single connection of DUT
- time basis 0.1 - 99.9 seconds (dwell time)
- optical and audible alarm
- min/max-limiting value comparator for all parameters / window comparator for setups
- micro processor controlled
- 100 setups with 300 steps per setup
- internal clock / calendar
- LC-display with 4 * 20 characters
- 24 VDC control interface / PLC remote control interface
- 24 VDC programme selection / PLC memory recall interface
- PC-control interface
Optional
- PC remote control software
Accessories
- hand operation unit
- protective wire test probe
- test dummy