Multi tester

LG 1800B
continuity: 24 VDC / protective wire: max. 30 AAC / insulation: 100 - 6000 VDC / high voltage: 5500 VAC / 6000 VDC / safety current limited / equivalent leakage current / function test
 
LG 3801E
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 1500 VDC / safety current limited / function test
 
LG 3801F
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 100 - 3000 VDC / high voltage: 100 - 3000 VDC / safety current limited /function test
 
LG 3881E
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 1500 VDC / safety current limited / leakage current: optional / function test
 
LG 3881F
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 100 - 3000 VDC / high voltage: 100 - 3000 VDC / safety current limited / leakage current: optional / function test
 
LG 3301D
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / function test
 
LG 3301E
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 1500 VDC / safety current limited / function test
 
LG 3301K
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 2200 VDC / safety current limited / function test
 
PM 3301E  (For testing acc. to EN 60 204)
continuity: max. 30 AAC / insulation: 500 VDC / high voltage: 1500 VDC, safety current limited
 
S 3301B
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 6000 VDC, safety current limited
 
S 3301E
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: max. 5000 VAC
 
S 3311B
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 6000 VDC / safety current limited
 
S 3311E
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 5000 VAC / 6000 VDC
 
KT 3881B
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 6000 VDC / safety current limited / leakage current: optional / function test
 
KT 3881 E/F/G/H/S
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 5500 / 6000 VDC / leakage current: optional / function test
 
KT 3301B
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 6000 VDC / safety current limited / function test
 
KT 3301D
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 1500 VDC / safety current limited / function test
 
KT 3301E
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 5000 / 6000 VDC / function test
 
KT 3301K
continuity: 22 VDC / protective wire: max. 30 AAC / insulation: 500 VDC / high voltage: 1500 VDC / safety current limited / function test